Fire safety is such an important issue that there are numerous safety classifications and international standards for which there are many different tests used to measure performance. The basis of most tests involves exposing a sample of a belt to the flame of a burner causing it to burn. The burner (flame) is then removed and the combustion time (duration of flame) of the test piece is recorded.

A current of air is then applied to the test piece for a specified time after the extinction of the flame. Under laboratory test conditions, Fenner Dunlop fire resistant belting consistently self-extinguishes more than 6 times faster (in less than one second) than the permissible pass rate average time of 7.5 seconds!

Available Cover and Rubber Compounds

Fire

Guardian ORX

Provides maximum oil resistance. Temperature range -30°F – 180°F. Surpass U.S occupational safety and Health Administration specifications for static conductivity. The cover is also flame retardant per MSHA Title 30, section 18.65 requirements.

Read more

Abrasion Fire Oil

FireBoss CSA-C OR

(Flame, Freeze, & Oil Resistance) Moderate oil resistant covers for grain handling. Compounded for colder operating climates. Temperature range -40 deg to 300 deg F (-40 def to 95 deg C). Surpasses U.S. Occupational Safety and Health Administration specifications for static conductivity. The cover is also flame retardant per MSHA…

Read more

Abrasion Fire Oil

FireBoss CSA-A2

Meets Canadian standards association M422- M87 current specification for Grade A2 Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications.

Read more

Fire

Guardian HF

High-quality grade II fire retardant compound. Compounded to be Halogen (Chlorine) free. Recommended for Power Generation facilities and Coal Prep Plants.

Read more

Abrasion Fire

FireBoss CSA-C AR

Fire Retardant cover compound with abrasion resistance for mining and industrial applications. Meets Canadian standards association M422- M87 current specification for Grade C or B2 For surface applications.

Read more

Fire Oil

Mining-FFOR

Fire retardant abrasion resistant compound that meets ASTM D378 Part 13.2. Medium Oil Resistant compound for Power Generation and Coal Preparation applications where oil resistance and MSHA specifications are required. For above ground applications. Static Conductive

Read more

Abrasion Fire

Guardian SAR

ARPM Grade I Fire retardant abrasion resistant compound that meets ARPM-FR Class 2 High-quality Grade I fire retardant compound specifically designed to counter the negative effects of leaching agents as well as dust suppressants. •Excellent abrasion and cover wear characteristics. •Recommended for Power Generation Facilities and Coal Prep Plants

Read more

Fire Oil

UGH 2.0

Provides maximum oil resistance to the destructive effects of grain oils and oil-based dust suppressant additives. Temperature range -30°F – 180°F. Surpass U.S occupational safety and Health Administration specifications for static conductivity. The cover is also flame retardant per MSHA Title 30, section 18.65 requirements. Designed for oil treated grain,…

Read more

Fire Oil

CGH 2.0

Moderate oil resistant covers for grain handling. Compounded for colder operating climates. The temperature range -40 to 200F Surpasses U.S. Occupational Safety and Health Administration specifications for static conductivity. CGH Cover Compound is also fame retardant per MSHA Title 30, Section 18.65 requirements. Electrical resistance to 300 megohms maximum. Designed…

Read more

Fire

Sahara FR

Offers performance in extreme hot material applications. Designed for hot exposure of limited duration up to 1000F without risk of melting or fire.

Read more

Abrasion Fire

FireBoss SAR

Meets MSHA Title 30 Part 14 B.E.L.T. standard. Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications.

Read more

Fire Oil

Guardian OR

Specifically designed to counter the negative effects of leaching agents as well as dust suppressants. Meets MSHA 2-G requirements. Increased resistance to abrasion and cover wear. Medium oil resistance where oil resistance is required. Recommended for power generation facilities and coal prep plants.

Read more

Abrasion Fire

MINING-FSAR

Meets U.S. Mine Safety and Health Administration requirements per MSHA Title 30, Section 18.65.

Read more

Abrasion Fire

MINING-FFSAR

High Quality Grade II Fire Retardant with excellent abrasion resistance.

Read more

Abrasion Fire

Guardian / Mining-FAR / Mining-FFAR

Specifically designed to counter the negative effects of leaching agents as well as dust suppressants. Meets MSHA 2-G requirements. Increased resistance to abrasion and cover wear. Recommended for power generation facilities and coal prep plants.

Read more

Abrasion Fire

Guardian AR

High quality grade II fire retardant compound specifically designed to counter the negative effects of leaching agents as well as dust suppressants. Meets MSHA 2-G requirements. Excellent abrasion and cover wear characteristics. Recommended for Power Generation facilities and Coal Prep Plants

Read more

Abrasion Fire

FireBoss

Meets MSHA Title 30 Part 14 B.E.L.T. standard. Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications.

Read more

Abrasion Fire

Fireboss AR

Meets MSHA Title 30 Part 14 B.E.L.T. standard. Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications. The only cover compound on the market to meet the stringent CSA-A2 standards. Exceeds ARPM FR class 1 requirements. Ideal when an increased fire retardant level…

Read more

Fenner Dunlop Conveyor Belting