Fire retardant
Fire safety is such an important issue that there are numerous safety classifications and international standards for which there are many different tests used to measure performance. The basis of most tests involves exposing a sample of a belt to the flame of a burner causing it to burn. The burner (flame) is then removed and the combustion time (duration of flame) of the test piece is recorded.
A current of air is then applied to the test piece for a specified time after the extinction of the flame. Under laboratory test conditions, Fenner Dunlop fire resistant belting consistently self-extinguishes more than 6 times faster (in less than one second) than the permissible pass rate average time of 7.5 seconds!
Available Cover and Rubber Compounds
Guardian ORX
Provides maximum oil resistance. Temperature range -30°F – 180°F. Surpass U.S occupational safety and Health Administration specifications for static conductivity. The cover is also flame retardant per MSHA Title 30, section 18.65 requirements.
FireBoss CSA-C OR
(Flame, Freeze, & Oil Resistance) Moderate oil resistant covers for grain handling. Compounded for colder operating climates. Temperature range -40 deg to 300 deg F (-40 def to 95 deg C). Surpasses U.S. Occupational Safety and Health Administration specifications for static conductivity. The cover is also flame retardant per MSHA…
FireBoss CSA-A2
Meets Canadian standards association M422- M87 current specification for Grade A2 Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications.
Guardian HF
High-quality grade II fire retardant compound. Compounded to be Halogen (Chlorine) free. Recommended for Power Generation facilities and Coal Prep Plants.
FireBoss CSA-C AR
Fire Retardant cover compound with abrasion resistance for mining and industrial applications. Meets Canadian standards association M422- M87 current specification for Grade C or B2 For surface applications.
Mining-FFOR
Fire retardant abrasion resistant compound that meets ASTM D378 Part 13.2. Medium Oil Resistant compound for Power Generation and Coal Preparation applications where oil resistance and MSHA specifications are required. For above ground applications. Static Conductive
Guardian SAR
ARPM Grade I Fire retardant abrasion resistant compound that meets ARPM-FR Class 2 High-quality Grade I fire retardant compound specifically designed to counter the negative effects of leaching agents as well as dust suppressants. •Excellent abrasion and cover wear characteristics. •Recommended for Power Generation Facilities and Coal Prep Plants
UGH 2.0
Provides maximum oil resistance to the destructive effects of grain oils and oil-based dust suppressant additives. Temperature range -30°F – 180°F. Surpass U.S occupational safety and Health Administration specifications for static conductivity. The cover is also flame retardant per MSHA Title 30, section 18.65 requirements. Designed for oil treated grain,…
CGH 2.0
Moderate oil resistant covers for grain handling. Compounded for colder operating climates. The temperature range -40 to 200F Surpasses U.S. Occupational Safety and Health Administration specifications for static conductivity. CGH Cover Compound is also fame retardant per MSHA Title 30, Section 18.65 requirements. Electrical resistance to 300 megohms maximum. Designed…
FireBoss SAR
Meets MSHA Title 30 Part 14 B.E.L.T. standard. Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications.
Guardian OR
Specifically designed to counter the negative effects of leaching agents as well as dust suppressants. Meets MSHA 2-G requirements. Increased resistance to abrasion and cover wear. Medium oil resistance where oil resistance is required. Recommended for power generation facilities and coal prep plants.
MINING-FSAR
Meets U.S. Mine Safety and Health Administration requirements per MSHA Title 30, Section 18.65.
Guardian / Mining-FAR / Mining-FFAR
Specifically designed to counter the negative effects of leaching agents as well as dust suppressants. Meets MSHA 2-G requirements. Increased resistance to abrasion and cover wear. Recommended for power generation facilities and coal prep plants.
Guardian AR
High quality grade II fire retardant compound specifically designed to counter the negative effects of leaching agents as well as dust suppressants. Meets MSHA 2-G requirements. Excellent abrasion and cover wear characteristics. Recommended for Power Generation facilities and Coal Prep Plants
Fireboss AR
Meets MSHA Title 30 Part 14 B.E.L.T. standard. Ideal when an increased fire retardant level is desirable. For underground Coal Mining Applications. The only cover compound on the market to meet the stringent CSA-A2 standards. Exceeds ARPM FR class 1 requirements. Ideal when an increased fire retardant level…